Fireplace Mantel Codes Clearance California. 2016 nfpa 211 11.2.5.4 clearance. As the building industry's preferred source in fireplace mantels, california mantel, inc.

How To Make A Wooden Briefcase
How To Make A Wooden Briefcase from s3.amazonaws.com

There are national fire codes that require all flammable materials to be at least 6 from the fireplace opening, and depending on the overhang and material of the mantel, that distance could be more. Wood beams, joists, studs and other combustible material shall have a clearance of not less than 2 inches (51 mm) from the front faces and sides of masonry fireplaces and not less than 4 inches (102 mm) from the back faces of masonry fireplaces. Is made of combustible material and protrudes 3 1/ from the wall.

How To Make A Wooden Briefcase

National fire code this ordinance states that any combustible material (such as a wood mantel surround or shelf) must be at least 6 inches from the fireplace opening. 2114.3.10 all combustible mantels and similar trim shall be kept at least 6 inches from fireplace opening. Parts of the mantel assembly located along the sides of the fireplace opening which project more than 1 1/2 inches (38mm) from the face of the fireplace shall have additional clearance equal to the projection extension beyond 1 1/2 inches. A discussion of national codes and local variations concerning the clearance from a fireplace opening to nearby combustible surfaces.